電器特性
Features
·Single–phase type motors
·Normally closed contacts type
·Solution to motor overheat and locked rotor
·Temperature and current dual protection
·Used in single and dual voltage type motors
·Variety mounting and terminal options
Specifications
·Contact type: Normally close (NC)
·Input power: 110-120VAC / 220-240VAC
·Full load current: 3A
·Terminal type : 3 Fast clip
·Reset: Manual Reset
·Base: Eared
·Horsepower: 1/6HP~5HP
·Operating temperature: Open-120°C / close-74°C
·Operating tolerance: ±5°C
·Resume temperature tolerance: ±12°C
Applications
·Industrial motors
·Various types of pumps
·Compressor
·Air conditioning
·Agricultural equipment
·Home appliances